ALBANY ACMACM / MCM PANEL SYSTEMS (home) Call or text (518) 888-7938 Free estimate

Field installation · Own insured crews

Commercial ACM and metal wall panel installation

Laser-aligned sub-framing, thermally broken clips, weather barriers and clean panel hanging across the Capital Region—for trays from our shop or yours.

Call or text (518) 888-7938

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: a crew hanging metal wall panels from a pipe scaffold

AI-generated illustration

AI-generated illustration: crew on pipe scaffold hanging ACM panels over an exterior barrier

Short answer

Our own insured crews install commercial ACM, MCM and single-skin metal wall panels across Albany and the Capital Region. Working from engineered shop drawings, we set girts, hat channels and thermally broken clip-and-rail sub-framing over air barriers and continuous insulation, hang wet-seal or dry-joint panels true to laser lines, and seal transitions at storefronts, masonry, EIFS and parapet copings.

Key facts

Service area
Albany, Schenectady, Troy, Saratoga Springs, Clifton Park, Glens Falls and jobs within about two hours of Albany.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

What goes on the wall before the first panel hangs

An ACM facade is only as straight and weathertight as the wall assembly behind it. Before a single panel tray comes out of the crate, our field crew inspects the exterior sheathing, substrate framing and rough openings against the approved shop drawings. Where our scope includes the weather plane, we apply or tie into the waterproofing air and water-resistive barrier, flash window perimeters and shelf reliefs, and fit continuous rigid or mineral wool insulation tight to the substrate.

Over the barrier and insulation, we install galvanized steel or aluminum Z-girts, hat channels or thermally broken clip-and-rail brackets spaced to match the engineered wind-load layout. Thermally broken clips reduce heat loss through metal framing and keep interior condensation away from the stud cavity during Albany winters.

Laser layout, girt shimming and crisp reveal lines

Structural steel and cold-formed stud walls rarely sit dead plumb from sill to parapet. If sub-framing simply follows wavy sheathing, flat ACM panels will telegraph out-of-plane steps at every four-way joint intersection. Our crews shoot horizontal and vertical laser benchmarks across the full elevation, establish fixed datum lines at storefront heads and soffit edges, and shim girts and vertical rails into one true plane before hanging trays.

Panels are hung in sequence—fastening perimeter tabs on wet-seal systems or setting hook-on extrusions onto rail pins on rainscreen systems—while checking joint width with calibrated spacers at every course. Consistent 1/2-inch reveals, plumb vertical joints and level horizontal sightlines are checked elevation by elevation, and directional arrows on the protective film are verified before each module is locked down.

Install-only crews for owner- or GC-furnished panels

Many national retail rollouts, corporate re-images and regional general contractors purchase pre-fabricated ACM packages directly from an out-of-state fabricator and need a dependable local crew to put the system on the building. Albany ACM Panels prices install-only contracts across the Capital Region. We unload and inventory crated shipments against the erection drawings, report any freight damage immediately, furnish sub-framing or sealants if excluded by the supplier, and hang the package with our own insured workforce.

When a field condition requires a filler strip, scupper trim or re-cut return, having our local panel fabrication shop in Albany means replacement pieces can be routed from matching stock without waiting weeks on long-haul freight. Because we own and erect supported pipe and frame scaffolding with our own crew—and operate boom and scissor lifts where grades allow—we control our own wall access safely from mobilization to punch list.

Transitions to glass, masonry, EIFS and parapet copings

Leaks and visual defects almost always show up at material changes rather than in the middle of a panel field. Our crews detail inside and outside corners, deep window jamb returns, canopy drip edges, soffit vents and brake-metal or plate panels parapet copings so water sheds cleanly off the facade. Where ACM meets brick, curtainwall aluminum, EIFS or stucco, we install bond-breaker backer rod and compatible perimeter sealants, then peel the factory protective film cleanly once overhead work is complete.

We work exclusively on commercial wall panels, canopies, soffits and sign bands—not metal roofs or residential siding—under The Dom Construction Group LLC's general liability, umbrella and workers' compensation coverage. Send drawings on our bid request page or call or text (518) 888-7938 to review schedule and access.

Field layout and hanging sequence

Methodical preparation behind the cladding keeps wide ACM modules flat and reveals straight.

  1. 1. Substrate, barrier and insulation check

    Inspect sheathing and openings, verify or install the air and water barrier, and secure continuous insulation.

  2. 2. Laser control lines and girt shimming

    Shoot horizontal and vertical datum lines across each elevation and shim girts, hat channels or thermally broken clips into plane.

  3. 3. Sequential panel hanging

    Hang labeled trays from scaffold or lifts, verify directional arrows and maintain uniform joint spacing with calibrated gauges.

  4. 4. Joint detailing, copings and film removal

    Install wet-seal silicone or dry-joint splines, close perimeter transitions to glass or masonry, and peel protective film.

Sub-framing, barriers and field hanging

AI-generated illustration: metal girts and clips over an air and water barrier, ready for panels

AI-generated illustration

AI-generated illustration: sub-framing girts and clips mounted over continuous insulation and barrier
AI-generated illustration: a metal panel soffit and canopy fascia over a storefront

AI-generated illustration

AI-generated illustration: commercial entry canopy and soffit framed for ACM cladding

Field installation and crew questions

What sub-framing goes behind ACM wall panels?

Sub-framing depends on the wall section and insulation thickness. Common setups include galvanized steel or aluminum Z-girts, hat channels over rigid insulation, or thermally broken fiberglass and aluminum clip-and-rail brackets supporting vertical tracks over an air and water-resistive barrier.

Will your crew install panels fabricated by an out-of-state supplier?

Yes. Install-only commercial panel work is one of our three standard contract options. Our crew unloads and checks crated shipments against the erection drawings, installs sub-framing and barriers when included in scope, hangs the panels and completes perimeter sealant joints.

How do you keep four-way panel intersections flush on uneven walls?

Backup stud and masonry walls almost always vary out of plane. Before hanging any trays, our installers shoot horizontal and vertical laser control lines across the elevation and shim girts or rail brackets so the mounting plane sits flat and plumb from end to end.

How do you access multi-story commercial elevations?

Depending on site paving, setbacks and building height, our crews work from boom and scissor lifts or from company-owned supported pipe and frame scaffold erected by our own crew. We do not use suspended stages.

When should the peel-off protective film come off the panels?

Protective film stays on during hanging and joint tooling to guard the PVDF finish against mortar, sealant smears and jobsite scratches, then comes off as each elevation finishes. Leaving film exposed to direct sun for many months can bake adhesive onto the coating.

Book a crew or price field installation

Send erection drawings or architectural elevations, target schedule and site access notes.

Rather text? Text photos to (518) 888-7938

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (518) 888-7938

    Call or text Monday–Friday, 7 AM–5 PM.

    Related facade and access scopes

    Looking for an insured crew to hang ACM?

    Book spring work now. Winter assessments and estimates available.