ALBANY ACMACM / MCM PANEL SYSTEMS (home) Call or text (518) 888-7938 Free estimate

Waterproofing · Albany & Capital Region

Commercial facade waterproofing, air barriers and joint sealants

Behind every dry ACM wall is a continuous air and water barrier, clean metal flashing, and properly backed silicone sealant joints at every perimeter transition.

Call or text (518) 888-7938

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: metal girts and clips over an air and water barrier, ready for panels

AI-generated illustration

AI-generated illustration: sub-framing girts mounted over a continuous air and water barrier on exterior sheathing

Short answer

Commercial panel walls stay dry only when the barriers, flashings, and joints behind and around them are detailed properly. Across Albany and the Capital Region, our own crews install air and water barriers over sheathing, sheet-metal perimeter flashings, backer rod and silicone joints on wet-seal facades, and breathable coatings, either alongside our ACM panel work or as a standalone scope.

Key facts

Service area
Albany, Schenectady, Troy, Saratoga Springs, Clifton Park, Glens Falls and jobs within about two hours of Albany.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

Air and water barriers behind rainscreen panels

Every open-joint or dry-joint rainscreen system assumes wind-driven rain and snowmelt will occasionally pass behind the outer panel face. What keeps the building dry is the continuous air and water-resistive barrier applied over the exterior sheathing before continuous insulation, thermally broken clips, and sub-framing girts go on the wall.

Our crews install fluid-applied and sheet-applied air and water barriers across commercial elevations, paying close attention to the transitions where water actually enters: rough-opening sill pans, window jamb and head tie-ins, structural steel penetrations, canopy outriggers, and roof-to-wall intersections. When clip fasteners penetrate the barrier plane to anchor Z-girts or hat channels, detailing those penetrations per the project's approved assembly keeps water out of the sheathing cavity. Where an FR-core ACM panel wall must match an NFPA 285 tested assembly, we install the exact barrier and insulation layers specified on the approved drawings.

Silicone wet-seal joints and facade transitions

On face-sealed wet-seal systems, the sealant joint between route-and-return panel returns is the primary weather line. Panel reveals, typically around half an inch wide, need clean return flanges, properly sized closed-cell backer rod set to uniform depth, and non-staining low-modulus silicone sealant tooled concave so the bead stretches cleanly across winter contraction and summer expansion.

Where panel fields terminate against aluminum storefront, curtain wall, brick masonry, EIFS, or cement stucco, joint geometry matters even more. Three-sided adhesion locks a sealant bead and tears it open during the first hard freeze, so we install bond-breaker tape or backer rod wherever depth is shallow and match sealant compatibility to adjacent substrates while protecting factory PVDF panel finishes with clean masking.

Sheet-metal flashings and breathable wall coatings

Sealant alone should never replace metal flashing at horizontal ledges, window heads, base-of-wall terminations, or parapet tops. We fabricate and set drip edges, through-wall flashings, sill pans, and transition trims, along with heavy-gauge aluminum plate copings that cap parapets without leaking at splice plates.

On mixed-material commercial buildings in Albany, Colonie, Clifton Park, Schenectady, and Troy, our crews also apply breathable elastomeric and architectural coatings to weathered concrete, CMU block, stucco, and EIFS elevations. Our field team brings about 19 years of experience in coatings, masonry, stucco, and EIFS, knowing when a wall needs a vapor-permeable coating that lets interior moisture escape rather than blistering in spring.

Why bundling waterproofing and panels prevents leaks

When one subcontractor applies the air barrier, another sets girts and panels, and a third caulks the perimeter, water intrusion turns into a finger-pointing exercise at every window corner and canopy pocket. As an exterior envelope subcontractor, The Dom Construction Group LLC can bundle air and water barriers, continuous insulation, sub-framing, panel installation, perimeter sealants, and our own supported scaffolding under one scope, or price waterproofing separately for general contractors and building owners.

We work with our own insured crews, carry general liability, umbrella, and workers' compensation coverage, and are registered on the New York State public work contractor registry. Send elevation drawings via our bid request page or call (518) 888-7938 Monday through Friday, 7 AM to 5 PM. We reply within one business day, Monday to Friday.

Facade sealant and barrier failures we correct

Where commercial wall assemblies usually let water bypass cladding in Capital Region freeze-thaw weather.

Split or cohesive-torn panel joints

Sealant beads pulled away from one return flange or split down the center of the reveal.

Usually means
Improper joint depth, missing backer rod causing three-sided adhesion, or rigid non-silicone caulk on metal panels.
What we do
Cut out failed sealant, clean return metal, set sized closed-cell backer rod or bond-breaker tape, and tool low-modulus silicone.

Damp sheathing behind open reveals

Interior moisture staining on rainscreen elevations that have no visible exterior face caulk.

Usually means
Gaps at window rough-opening flashings, unsealed air-barrier laps, or undetailed sub-framing clip penetrations.
What we do
Expose affected bays, tie continuous air and water barrier membrane into rough openings and penetrations, and re-hang panels.

Streaking below parapet caps

Dark runoff tracks or winter icicles forming directly beneath coping splice joints.

Usually means
Flat unsloped coping tops, missing internal gutter cleats, or dried-out lap sealant at metal splice plates.
What we do
Install sloped aluminum plate copings with continuous cleats, internal splice plates, and flexible silicone joint seals.

Peeling coatings on adjacent masonry or stucco

Bubbled, flaking paint along CMU, concrete, or cement plaster bands next to metal cladding.

Usually means
Vapor-impermeable exterior paint trapping outbound wall moisture ahead of winter freezes.
What we do
Remove loose film, repair substrate cracks, and recoat with a breathable elastomeric or mineral facade coating.
AI-generated illustration: a wet-seal ACM joint with backer rod and silicone sealant

AI-generated illustration

AI-generated illustration: backer rod and silicone sealant joint between route-and-return wall panels

Commercial facade waterproofing questions

Why use silicone instead of polyurethane sealant in ACM wet-seal joints?

Aluminum composite and solid aluminum panels expand and contract quickly when direct sun warms dark PVDF finishes on cold winter mornings. Low-modulus neutral-cure architectural silicone stays flexible across wide temperature swings and strong UV exposure without chalking, hardening, or pulling loose from coated aluminum returns. Non-staining formulations are selected where joints meet porous stone, precast concrete, or adjacent masonry.

Does an open-joint rainscreen wall still need caulking anywhere?

Yes, at perimeter transitions and air-barrier terminations rather than between every panel module. While open panel reveals stay unsealed so air circulates and incidental moisture drains down the rear cavity, critical sealant joints are still required around window and storefront perimeters, louver frames, expansion joints, roof-to-wall flashings, and penetrations through the underlying air and water-resistive barrier.

What causes three-sided adhesion failure in commercial facade joints?

An elastomeric sealant bead is meant to bond only to the two opposite panel returns so its center can stretch freely like a rubber band. If sealant also bonds to a rigid bottom surface at the back of the joint, thermal movement concentrates stress along the edges and tears the bead. Closed-cell backer rod or bond-breaker tape prevents rear adhesion.

How are sub-framing clip penetrations handled over an air and water barrier?

Every thermally broken clip or Z-girt anchor passes through the exterior insulation plane and fastens through the air and water-resistive barrier into framing or masonry. Depending on the barrier manufacturer and NFPA 285 assembly details on the drawings, installers bed clips over self-sealing butyl gaskets, compatible fluid-applied detailing mastic, or tested washered fasteners so wind-driven cavity water stays outside the sheathing.

What makes a breathable facade coating different from standard exterior paint?

Standard thick latex or alkyd paints can form a vapor-tight skin that traps migrating interior moisture behind masonry, cement stucco, or EIFS until freeze-thaw pressure blisters the film. Breathable elastomeric and mineral-silicate facade coatings bridge hairline surface cracks and shed wind-driven rain from the outside while maintaining high water-vapor permeability so damp wall substrates can dry outward safely.

Request pricing for barriers, sealants or coatings

Send elevation drawings or wall photos for standalone facade waterproofing or a combined panel envelope bid.

Rather text? Text photos to (518) 888-7938

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (518) 888-7938

    Call or text Monday–Friday, 7 AM–5 PM.

    Connected wall systems we install

    Want one crew for the air barrier and the panels?

    Book spring work now. Winter assessments and estimates available.